Detector Upgrades for the mardtb Goniostat
!!! BREAKING NEWS !!!
For North American customers, marXperts and DECTRIS USA have teamed up to supply sales and service for mardtb/DECTRIS systems in the U.S. and Canada from the DECTRIS USA office in Philadelphia.
marXperts proudly offers the full range of hybrid photon-counting laboratory detectors of DECTRIS, namely the EIGER(2) R and PILATUS3 R series, as upgrade of a mar345dtb or marccddtb X-ray data collection system. Essentially, any existing mardtb goniostat can be equipped with DECTRIS detectors. And it is easy to do. Take advantage of the unmatched read-out speed and the incredible low noise of the DECTRIS detectors and benefit from shutterless data collections. Make your X-ray setup state-of-the-art again. And what, if you combine everything with a metaljet X-ray generator?
Upgrades for mar345dtb/marccd data collection systems:
![]() |
EIGER(2) R 4M hybrid photon counting detector:
|
![]() |
PILATUS3 S 2M hybrid photon counting detector:
The PILATUS3 2M detector is available only as high-speed S and X versions, not as laboratory "R" version. It does fit on the mardtb, though, and can be used either on a synchrotron beamline or a laboratory X-ray source. |
![]() |
PILATUS3 R 1M hybrid photon counting detector:
|
![]() |
PILATUS3 R 300K-A hybrid photon counting detector:
|
![]() |
PILATUS3 R 200K-A hybrid photon counting detector:
|
![]() |
X-ray Generator: Excillum D2+ 70kV MetalJet microfocus X-ray generator operating at 250 Watts (70 kV, 3.5 mA) and with 2 usable ports, typically producing a spot with a size of approx. 20 by 20 µm or smaller at the source. The generator does not require special water and electrical installations. Other models of the MetalJet generator are available, e.g. an entry level version using the same liquid metal technology but a simpler elecron focussing device and hence smaller X-ray flux. |
Highlights:
Extremely short detector read-out allows for fine φ-slicing |
Very small pixel size of only 75 µm (EIGER & EIGER2) or 172 µm (PILATUS3) |
Shutterless data collection |
Extremely high sensitivity |
Extremely low noise |
High dynamic range (up to 32 bits) |
No point-spread due to direct conversion leading to small spots with better I/σ |
Fast screening experiments |
Downloads:
- Product flyer Eiger R 4M (mar4M) (pdf: 1.2 MB)
- Product flyer PILATUS3 R 1M (mar1M) (pdf: 1.2 MB)
- Product flyer PILATUS3 R 200K (mar200k) (pdf: 1.2 MB)
- Product brochure metaljet(pdf: 2.0 MB)
- Application note mar.AN12Mar15 (pdf: 0.6 MB)
"Sulfur-SAD phasing of lysozyme at room temperature with a PILATUS3 R 200K-A detector on a marYX2G micro-beam generator" - Application note mar.AN31Jul15 (pdf: 1.4 MB)
"Sulfur-SAD phasing of lysozyme with a PILATUS3 R 1M detector on a marYX2G micro-beam generator" - Application note mar.AN29May18 (pdf: 1.0 MB)
"Atomic resolution data collection with the PILATUS3 R 1M detector on a metaljet X-ray source" - Application note mar.AN07Sep17 (pdf: 0.6 MB)
"High speed and high resolution data collection with an EIGER R 4M detector mounted on a mardtb goniostat."