Detector Upgrades for the mardtb  Goniostat

!!! BREAKING NEWS !!!
For North American customers, marXperts and DECTRIS USA have teamed up to supply sales and service for mardtb/DECTRIS systems in the U.S. and Canada from the DECTRIS USA office in Philadelphia.

  • EIGER R 4M: 2 x 4 modules, 155 x 163 mm active area, 2070 x 2167 pixels, 5 frames/second

    Eiger 4M detector

  • PILATUS3 R 1M: 2 x 5 modules, 169 x 180 mm active area, 981 x 1043 pixels, 7 ms read-out time

    Pilatus3 1M detector on mardtb

  • PILATUS3 R 200K-A: 2 modules, 84 x 70 mm active area, 487 x 407 pixels, 7 ms read-out time, air-cooled

    Pilatus3 200K-A detector on mardtb

  • PILATUS3 S 2M: 3x8 modules, 254 x 289 mm active area, 1475 x 1679 pixels, 2 ms read-out time


    Pilatus3 S 2M detector

  • PILATUS3 R 1M: 2 x 5 modules, 169 x 180 mm active area, 981 x 1043 pixels, 7 ms read-out time

    Pilatus3 1M detector

  • PILATUS3 R 200K-A: 2 modules, 84 x 70 mm active area, 487 x 407 pixels, 7 ms read-out time, air-cooled

    Pilatus3 200K-A detector

  • PILATUS3 R 300K-A: 3 modules, 84 x 106 mm active area, 487 x 619 pixels, 7 ms read-out time, air-cooled

    Pilatus3 300K-A detector

marXperts proudly offers the full range of hybrid photon-counting laboratory detectors of DECTRIS, namely the EIGER(2) R and PILATUS3 R series, as upgrade of a mar345dtb or marccddtb X-ray data collection system. Essentially, any existing mardtb goniostat can be equipped with DECTRIS detectors. And it is easy to do. Take advantage of the unmatched read-out speed and the incredible low noise of the DECTRIS detectors and benefit from shutterless data collections. Make your X-ray setup state-of-the-art again. And what, if you combine everything with a metaljet X-ray generator?

Upgrades for mar345dtb/marccd data collection systems:

 
EIGER(2) R 4M pixel detector EIGER(2) R 4M hybrid photon counting detector:
  • 155 x 162 mm active area
  • 2 x 4 modules
  • 75 µm pixelsize
  • continuous read-out
Pilatus3 S 2M PILATUS3 S 2M hybrid photon counting detector:
  • 169 x 180 mm active area
  • 2 x 5 modules
  • 172 µm pixelsize
  • 7 ms read-out time

The PILATUS3 2M detector is available only as high-speed S and X versions, not as laboratory "R" version. It does fit on the mardtb, though, and can be used either on a synchrotron beamline or a laboratory X-ray source. 

Pilatus3 R 1M PILATUS3 R 1M hybrid photon counting detector:
  • 169 x 180 mm active area
  • 2 x 5 modules
  • 172 µm pixelsize
  • 7 ms read-out time
Pilatus3 R 300K PILATUS3 R 300K-A hybrid photon counting detector:
  • 84 x 106 mm active area
  • 3 modules
  • 172  µm pixelsize
  • 7 ms read-out time
Pilatus3 R 200K PILATUS3 R 200K-A hybrid photon counting detector:
  • 84  x 70 mm active area
  • 2 modules
  • 172 um pixelsize
  • 7 ms read-out time
MetalJet D2+ 70kV X-ray Generator:
Excillum D2+ 70kV MetalJet microfocus X-ray generator operating at 250 Watts (70 kV, 3.5 mA) and with 2 usable ports, typically producing a  spot with a size of approx. 20 by 20 µm or smaller at the source. The generator does not require special water and electrical installations. Other models of the MetalJet generator are available, e.g. an entry level version using the same liquid metal technology but a simpler elecron focussing device and hence smaller X-ray flux.

Highlights:

Extremely short detector read-out allows for fine φ-slicing
Very small pixel size of only 75 µm (EIGER & EIGER2) or 172 µm (PILATUS3)
Shutterless data collection
Extremely high sensitivity
Extremely low noise
High dynamic range (up to 32 bits)
No point-spread due to direct conversion leading to small spots with better I/σ  
Fast screening experiments